Deluge Alarm Valve Preaction Alarm Valve, Check Valve

Product Details
Customization: Available
Type: Outdoor Fire Hydrant
Decompression: Normal Fire Hydrant
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
258
Year of Establishment
1993-09-04
  • Deluge Alarm Valve Preaction Alarm Valve, Check Valve
  • Deluge Alarm Valve Preaction Alarm Valve, Check Valve
  • Deluge Alarm Valve Preaction Alarm Valve, Check Valve
  • Deluge Alarm Valve Preaction Alarm Valve, Check Valve
  • Deluge Alarm Valve Preaction Alarm Valve, Check Valve
  • Deluge Alarm Valve Preaction Alarm Valve, Check Valve
Find Similar Products

Basic Info.

Rotation
Ordinary Bolt
Outdoor Fire Hydrant Type
High-Pressure Fire Hydrant
Fire Hydrant Type
Ordinary
Rate Working Pressure
12bar
Seal Test
24bar
Strength Test
48bar
Transport Package
Packing by Wood Box
Specification
ZSFU100
Trademark
sanxing
Origin
Quanzhou, Fujian, China
HS Code
8481804090

Product Description

product description

pre-action systems are usally employed in areas that are at risk for serious water damage due to damaged sprinklers and/or piping.they operate faster than dry systems.
the pre-action system is a fire extinguishing system with the nozzles normally closed.the pipe network is usually not filled with water.
when a fire occurs,after the fire detector alarms ,the automatic control system controls the valve exhaust and water filling,and changes from a dry type to a wet type system.water sprayinh only started when the ignition point temperature reached the open and closed sprinkler.
the pre-action system has the characteristics of both a dry sprinkler system and a wet sprinkler system,and also overcomes the shortcomings of the dry sprinkler system's low fire control rate and the wet system's prone to water stains.
the system can increase the speed of fire extinguishing .it can also be used in places where pipes and sprinklers are easily damage, instead of wet systems.it ccan alsobe used in buildings with high safety requirements for sprinkler systems.




Deluge Alarm Valve Preaction Alarm Valve, Check Valve
Deluge Alarm Valve Preaction Alarm Valve, Check Valve
Deluge Alarm Valve Preaction Alarm Valve, Check Valve

technical parameters
specification ZSFU100 ZSFU150 ZSFU200
nominal diameter(mm) 100 150 200
rate working pressure(Mpa) 1.2 1.2 1.2
valve body height(mm) 260 270 370
flange diameter(mm) 220 285 340
systemtric hole diameter(mm) 180 240 295
screw hole number and diameter(mm) 8*Φ18 8*Φ22 12*Φ22

working principle
Deluge Alarm Valve Preaction Alarm Valve, Check Valve

Deluge Alarm Valve Preaction Alarm Valve, Check Valve
Deluge Alarm Valve Preaction Alarm Valve, Check ValveDeluge Alarm Valve Preaction Alarm Valve, Check ValveDeluge Alarm Valve Preaction Alarm Valve, Check ValveDeluge Alarm Valve Preaction Alarm Valve, Check ValveDeluge Alarm Valve Preaction Alarm Valve, Check Valve


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier