• Tianxing Zsfz 100 Pre-Action Alarm Valve Deluge Dry Wet Fire Alarm Check Valve System
  • Tianxing Zsfz 100 Pre-Action Alarm Valve Deluge Dry Wet Fire Alarm Check Valve System
  • Tianxing Zsfz 100 Pre-Action Alarm Valve Deluge Dry Wet Fire Alarm Check Valve System
  • Tianxing Zsfz 100 Pre-Action Alarm Valve Deluge Dry Wet Fire Alarm Check Valve System

Tianxing Zsfz 100 Pre-Action Alarm Valve Deluge Dry Wet Fire Alarm Check Valve System

Sprinkler Installation: Ordinary
Sprinkler Head Type: Open
Alarm Valve Type: Deluge Valve
Automatically Opened and Closed Repeatedly: Can Automatically Opened and Closed
Open Fire Sprinkler System Type: Deluge System
Closed Fire Sprinkler System: Preaction Fire Sprinkler System
Customization:
Diamond Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Supplier′s popular products
  • Product Description
  • Related Products
  • Company Profile
  • Successful Cases
  • FAQ
Overview

Basic Info.

Model NO.
Pre-Action Alarm Valve
Surface Finishing
Painting Red
Material
Ductile Iron
Rated Working Pressure
1.2MPa
Transport Package
Packing by Wood Box
Trademark
Tianxing
Origin
Quanzhou, Fujian, China
HS Code
5909000000
Production Capacity
1000/Month

Product Description

Supplier's popular products
 
Tianxing Zsfz 100 Pre-Action Alarm Valve Deluge Dry Wet Fire Alarm Check Valve System
Tianxing Zsfz 100 Pre-Action Alarm Valve Deluge Dry Wet Fire Alarm Check Valve System
Tianxing Zsfz 100 Pre-Action Alarm Valve Deluge Dry Wet Fire Alarm Check Valve System

 

Product Description

Pre-action Alarm Valve

Pre-action systems are usually employed in areas that are at risk for series water damage due to damaged sprinklers and piping. They operate faster than dry system.

Technical Parameters

Specification Nominal Diameter(mm) Rate Working pressure(MPa) Valve Body Height(mm) Flange Diameter(mm) Symmetric Hole Diameter(mm) Screw Hole Number and Diameter(mm)
ZSFU100 100 1.2 260 220 180 8 x φ18
ZSFU150 150 270 285 240 8 x φ22
ZSFU200 200 370 340 295 12 x φ22

Tianxing Zsfz 100 Pre-Action Alarm Valve Deluge Dry Wet Fire Alarm Check Valve System
Dry Alarm Valve


ZSFC Dry alarm valve, which is applicable in low and high temperature environment, is the control valve of dry sprinkler system.


Technical Parameters

Specification Rate Working Pressure(MPa) Seal Test(MPa) Strength Test(MPa) Nominal Diameter Flange Diameter (mm) Symmetric Hole Diameter(mm) Screw Hole Number and Diameter(mm)
ZSFC100 1.2 2.4 4.8 DN100 220 180 8 x φ18
ZSFC150 DN150 285 240 8 x φ22
ZSFC200 DN200 340 295 12 x φ22

Tianxing Zsfz 100 Pre-Action Alarm Valve Deluge Dry Wet Fire Alarm Check Valve System

Deluge Alarm Valve
ZSFM Deluge alarm valve is a kind of lever-type structure with anti-reset function. It is widely used for various types of dry systems.

Technical Parameters

Specification Rate Working Pressure(MPa) Seal Test(MPa) Strength Test(MPa) Nominal Diameter(mm) Flange DIameter(mm) Symmetric Hole Diameter(mm) Screw Hole Number and Diameter(mm)
ZSFM65 1.2 2.4 4.8 DN65 185 145 4 x 18
ZSFM80 DN80 200 160 8 x 18
ZSFM100 DN100 220 180
ZSFM125 DN125
ZSFM150 DN150 285 240 8 x 22
ZSFM200 DN200 340 295 12 x 22
ZSFM250 DN250 405 355 12 x 26

Tianxing Zsfz 100 Pre-Action Alarm Valve Deluge Dry Wet Fire Alarm Check Valve System

Wet Alarm Valve
ZSFZ Wet alarm valve is the key component of automatic sprinkler system. It consist of valve body, delayer, water motor alarm and other components. It is used in places where fire can be extinguished by water.

Technical Parameters

Specification Nominal Diameter (mm) Rate Working Pressure(MPa) Strength Test (MPa) Seal Test (MPa) Friction Pesistance(MPa) Response Time(s)
ZSFZ-100 DN100 1.2 2.4 4.8 <0.07 <15
ZSFZ-125 DN125
ZSFZ-150 DN150
ZSFZ-200 DN200


Tianxing Zsfz 100 Pre-Action Alarm Valve Deluge Dry Wet Fire Alarm Check Valve System

 
Related Products
Tianxing Zsfz 100 Pre-Action Alarm Valve Deluge Dry Wet Fire Alarm Check Valve System

 

Company Profile

Tianxing Zsfz 100 Pre-Action Alarm Valve Deluge Dry Wet Fire Alarm Check Valve System

Tianxing Zsfz 100 Pre-Action Alarm Valve Deluge Dry Wet Fire Alarm Check Valve SystemTianxing Zsfz 100 Pre-Action Alarm Valve Deluge Dry Wet Fire Alarm Check Valve System

 

Successful Cases



Tianxing Zsfz 100 Pre-Action Alarm Valve Deluge Dry Wet Fire Alarm Check Valve System

 

FAQ



Choosing us is the right decision!

1. Are you a factory or trading company?
    We are a professional manufacturer. We warmly welcome clients from worldwide to visit our factory
    and cooperate with us. We can offer OEM & ODM service.


2.
Can you produce goods with special specification ?
   Our company focuses on customized products.First of all, we need to know the specification in details,   and then we need to check with our technology department. We will give customers satisfying reply as soon as possible.

3.  How long is the delivery time?
    30-45 days after the advance payment.

4.
What's your advantage?
    Independent R&D team,professional production and sales team,great production capacity sustainable      supply.Use the best material and production process.Low defective rate.


5. How can we guarantee quality?
   Always a pre-production sample before mass production;
   Always final Inspection before shipment;

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.