• Deluge Valve for Fire Alarm System
  • Deluge Valve for Fire Alarm System
  • Deluge Valve for Fire Alarm System
  • Deluge Valve for Fire Alarm System
  • Deluge Valve for Fire Alarm System
  • Deluge Valve for Fire Alarm System

Deluge Valve for Fire Alarm System

Type: Outdoor Fire Hydrant
Decompression: Normal Fire Hydrant
Rotation: Ordinary Bolt
Outdoor Fire Hydrant Type: High-Pressure Fire Hydrant
Fire Hydrant Type: Ordinary
Rate Working Pressure: 12bar
Customization:
Diamond Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
ZSFM80
Seal Test
24bar
Strength Test
48bar
Transport Package
Packing by Wood Box
Specification
ZSFM80
Trademark
sanxing
Origin
Quanzhou, Fujian, China
HS Code
8481804090

Product Description

product description
the shower valve is a direct-sealed diaphragm valve.the valve body is made of high-quality cast iron.the diaphragm is made of cloth-butyl rubber material.
it has the characteristics of durability,reliable performance,flexible installation and convenient maintenance.
there are no components such as shafts and metak discs in the valve,so there is no problem of corrosion.
it is widely used in variousopen systems (open sprinklers on the system side pipes)such as rain shower systems,water curtain systems,and water mist systems.
this valve is manufactured according to GB5135.5-2003 standard.the rain sprinkler valve and various open sprinklers form a rain sprinkler system,also an open fire suppression system.
once the rain sprinkler valve is opened,all open sprinklers connected behind the valve spray water at the same time,so the rain sprinkler system is suitable for high-speed fire spreading ,and the closed sprinklercan not effectively cover the fire area when the sprinkler is opened,due to the high space,the closed sprinkler cannot move in time.such as stage,pyrotechnic factory and other  places with serious danger level ll(solvent,paint,asphalt,etc.).
because the rain shower system is a facility with a single active area,it must be designed accoring to specifictions.the protection range of a  rain shower valve must not exceed 260m2.

Deluge Valve for Fire Alarm System
Deluge Valve for Fire Alarm System
Deluge Valve for Fire Alarm System
Deluge Valve for Fire Alarm System

technical parameters
specification ZSFM65 ZSFM80 ZSFM100 ZSFM125 ZSFM150 ZSFM200 ZSFM250
rate working pressure(Mpa) 1.2 1.2 1.2 1.2 1.2 1.2 1.2
seal  test(Mpa) 2.4 2.4 2.4 2.4 2.4 2.4 2.4
strength test(Mpa) 4.8 4.8 4.8 4.8 4.8 4.8 4.8
nominal diameter(mm) DN65 DN80 DN100 DN125 DN150 DN200 DN250
flange diameter(Mpa) 185 200 220 220 285 340 405
sysmmetric hole diameter(mm) 145 160 180 180 240 295 355
screw hole number and diameter(mm) 4*18 8*18 8*18 8*18 8*22 12*22 12*26


working principle
Deluge Valve for Fire Alarm System


Deluge Valve for Fire Alarm System

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now